EasyManuals Logo
Home>Delta Electronics>DC Drives>AC Servo Drive ASDA-AB

Delta Electronics AC Servo Drive ASDA-AB User Manual

Delta Electronics AC Servo Drive ASDA-AB
357 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #212 background imageLoading...
Page #212 background image
Chapter 7 Servo Parameters|ASDA-AB Series
Revision January 2009 7-63
P2 - 33â–²
INF Easy Setting of Input Filter Communication Addr.: 0221H
Default: 0 Related Section:
Applicable Control Mode: ALL Section 6.3.6
Unit: N/A
Range: 00 ~ 19
Settings:
not used
A
B
• A: Speed selection
Low speed
High speed
A=0
A=9
• B=1: Enable this function
P2 - 34
SDEV Overspeed Warning Condition Communication Addr.: 0222H
Default: 5000 Related Section: N/A
Applicable Control Mode: S
Unit: r/min
Range: 1 ~ 5000
Settings:
This parameter is used to set the over speed condition of the drive fault code. (See P0-01)
P2 - 35
PDEV Excessive Error Warning Condition Communication Addr.: 0223H
Default: 30000 Related Section: N/A
Applicable Control Mode: Pt, Pr
Unit: pulse
Range: 1 ~ 30000
Settings:
This parameter is used to set the excessive error condition of the drive fault code (See P0-01) .
As for the proportion value setting of position excessive error warning condition, please refer to
P2-63.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta Electronics AC Servo Drive ASDA-AB and is the answer not in the manual?

Delta Electronics AC Servo Drive ASDA-AB Specifications

General IconGeneral
BrandDelta Electronics
ModelAC Servo Drive ASDA-AB
CategoryDC Drives
LanguageEnglish

Related product manuals