05 Multi-step Speed Operation
You can set this parameter during operation.
05.00
1
st
Step Speed Frequency
05.01
2
nd
Step Speed Frequency
05.02
3
rd
Step Speed Frequency
05.03
4
th
Step Speed Frequency
05.04
5
th
Step Speed Frequency
05.05
6
th
Step Speed Frequency
05.06
7
th
Step Speed Frequency
Default: 0.00
Settings
0.00–400.00 Hz
Use the multi-function input terminals (refer to Pr.04.0604-08) to select the multi-step speed
command (the maximum is 7th step speed). Pr.05.00 to Pr.05.06 sets the multi-step frequency
as shown in the following table.
Pr.
Multi-Step Speed
Command 1
Multi-Step Speed
Command 2
Multi-Step Speed
Command 3
Master
Frequency
Master Speed
OFF
OFF
OFF
1st Step
Speed
05.00
ON
OFF
OFF
2nd Step
Speed
05.01
OFF
ON
OFF
3rd Step
Speed
05.02
ON
ON
OFF
4th Step
Speed
05.03
OFF
OFF
ON
5th Step
Speed
05.04
ON
OFF
ON
6th Step
Speed
05.05
OFF
ON
ON
7th Step
Speed
Frequency
05.06
ON
ON
ON