Chapter 7 Troubleshooting _VFD-B Series
Revision 10/2005, BE13, SW V4.08 7-7
7.10 Motor Speed cannot be Changed
Motor can run but
cannot change speed
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
Yes
No
No
No
No
No
No
No
No
No
No
Check if the setting of the
max. frequency is too low
If the setting of frequency
is out of range(upper/lower)
bound
Modify the setting
Modify the setting
Yes
No
Yes
If the setting of
Pr.05-17toPr.05-31
is too high
Yes
If finished with
executing
Pr.05-15
If the setting of
Pr.05-00 to Pr.05-14
are the same
If it is in PLC mode
Press UP/DOWN key
to see if speed has
any change
If there is any change
of the signal that sets
frequency (0-10V and
4-20mA)
Check if the wiring between
M1~M6 to DCM is correct
Connect
correctly
Check if frequency for
each step is different
Check if the wiring of
external terminal is correct
Change frequencysetting
If accel./decel. time
is very long
Please set suitable
accel./decel. time by
load inertia
Maybe AC motor drive has malfunction or misoperation
due to noise. Please contact with DELTA.
Change defective
potentiometer

Table of Contents

Other manuals for Delta VFD110B43A

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Delta VFD110B43A and is the answer not in the manual?

Delta VFD110B43A Specifications

General IconGeneral
BrandDelta
ModelVFD110B43A
CategoryDC Drives
LanguageEnglish

Related product manuals