37
Error code table with disk version up
Error Code Details of Error code
01 Tray Open/Close failure
02 No Disc
03 Disc error(TOC not read )
04 No update le
05 Update le read error
10 Update le check sum error
11 Erase failure
12 Write failure
13 Verify uncorrect
20 Update le check sum error
21 Erase failure
22 Write failure
23 Verify uncorrect
24 Communication error
30 Update failure check sum error
31 Erase failure
32 Writef failure
33 Verify failure
34 Communication error
B2 DM8x0 rmware rewrite error information received
10. DPMS UP date mode
Update the rmware of DPMS.
Refer to [ VERSION UPGRADE PROCEDURE OF FIRMWARE "2. How to update by DPMS" ].
Error code table
Preparation operation rewritten, Update error code checking. (Check ETHERNET unit)
Error Code Details of Error code Coping strategies
01 Login failed(DPMS Access Login Incorrect notication) Reset and update again. Carry out the update in an environment
that has little network load.
02 Login failed(DPMS Access Server Busy information) Carry out the update in an environment that has little network
load.
03 Login failed(DPMS Access link failure information) Check the network connection. Carry out the update in an
environment that has little network load.
04 Firm Info response acquisition error recived Check the network connection. Carry out the update in an
environment that has little network load.
05 Firm Info response acquisition TimeOut Check the network connection. Carry out the update in an
environment that has little network load.
06 All Firm Info response acquisition error recived Check the network connection. Carry out the update in an
environment that has little network load.
07 All Firm Info response acquisitionTimeOut Check the network connection. Carry out the update in an
environment that has little network load.
08 Main Firm Info response acquisition error recived Check the network connection. Carry out the update in an
environment that has little network load.
09 Main Firm Info response acquisition TimeOut Check the network connection. Carry out the update in an
environment that has little network load.
0A DownLoad failed ((NG)information recieved) Check the network connection. Carry out the update in an
environment that has little network load.
0B DownLoad failed((ServerBusy) information recieved) Check the network connection. Carry out the update in an
environment that has little network load.
0C DownLoad failed((connection failed)information
recived)
Check the network connection. Carry out the update in an
environment that has little network load.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Denon RCD-N8 and is the answer not in the manual?

Denon RCD-N8 Specifications

General IconGeneral
Remotely operatedYes
Security algorithmsWPS
Supported radio bandsFM, VHF
Built-in storage mediaNo
Audio formats supportedMP3
Internet radio services supportediDevice, iTunes
Network streaming services supported-
Product colorWhite
RMS rated power130 W
Wi-Fi standards802.11b, 802.11g
Digital audio optical out1
Apple docking compatibilityiPhone, iPod
AC input voltage230 V
AC input frequency50 Hz
Power consumption (typical)50 W
Weight and Dimensions IconWeight and Dimensions
Depth299 mm
Width280 mm
Height112 mm