Digi Connect and ConnectPort TS Family web interface Configuration through the web interface
Digi Connect Family and ConnectPort TS Family
63
Automatic TCP connections (Automatic Connection)
The TCP Client allows the Digi Connect and ConnectPort TS Family product to automatically establish
a TCP connection to an application or a network, known as autoconnection. You can enable
autoconnection through the TCP Sockets profile’s setting labeled Automatically establish TCP
connections. When you set the TCP Sockets profile, the DTR flow-control signal indicates when a TCP
socket connection has been established. You can use this information when monitoring the serial line.
You can use it as a flow-control mechanism to determine when the Digi device connects to a remote
device establishes communication. You can combine this mechanism with the DCD signal to close the
connection and the DSR signal to do RCI over serial. Together, you can use these signals to the Digi
device to auto connect to many devices, deterministically, on the network.
TCP and UDP network port numbering conventions
Digi devices use the following conventions for TCP and UDP network port numbering:
For this connection type... Use this Port
Telnet to the serial port
The format for this port number is as follows:
20<serial port number>
Replace <serial port number> with the Digi serial
port number. For example, 2001 applies to serial
port 1, 2010 applies to serial port 10, and 2016
applies to serial port 16.
2001 (TCP only)
Raw connection to the serial port
The format for this port number is as follows:
21<serial port number>
Replace <serial port number> with the Digi serial
port number. For example, 2101 applies to serial
port 1, 2110 applies to serial port 10, and 2116
applies to serial port 16.
2101 (TCP and UDP)
The application or Digi Connect and ConnectPort TS Family device that initiates communication must
use these network ports numbers. If you cannot configure the application or Digi Connect and
ConnectPort TS Family product to use these network port numbers, change the network port on the
Digi Connect and ConnectPort TS Family product.
RFC 2217
Use the RFC 2217 protocol to access serial devices over the network. RFC 2217 implementations
enable applications to set the parameters of remote serial ports (for example, baud rate or flow
control), detect line signal changes, as well as receive and transmit data. The configuration
information provided in this section applies to Digi device functioning as RFC 2217 servers. If using the
RFC 2217 protocol, do not modify the port settings from the defaults. If the port settings have been
changed, restore the factory default settings (see Factory default settings). No additional
configuration is required.

Table of Contents

Other manuals for Digi Connect ME

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digi Connect ME and is the answer not in the manual?

Digi Connect ME Specifications

General IconGeneral
BrandDigi
ModelConnect ME
CategoryNetwork Hardware
LanguageEnglish

Related product manuals