The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely confi dential. Any disclosure, copying, distribution to third
party
is strictly prohibited.
14
“E-Seal”- Electronic Sealing:
1st Sec on: Last 100 Reading Changes Done
The “E-Seal” is a non-erasable memory spli ed in two sec ons where, in the fi rst sec on, are recorded the last 100
altera ons made on the programming func ons. These are shown on the displays or printed, with detailed informa-
on of: index nr, event, date, year and hour. The second sec on is made of permanent, non-rese able, progressive
individual events counter, incremented by each event altera ons without details. The fi rst sec on is by default a FIFO
buff er, with the last 100 events recorded, but can be confi gured by tariff to disable the FIFO and block the taximeter
when it reaches its maximum capacity. The second sec ons (counters) is never FIFO, and when reaches its maximum
capacity of 1000 events on any counter, the taximeter shows “ESEAL FULL” and it is blocked un l the mechanical seal
is broken and the taximeter is again ini alized.
The “E-Seal” Reading, is included in the “SelfFun on Menu”. This is the procedure to enter it:
1) Keep pressed K2 at least for two seconds to enter in the menu selec on
2) Select E-Seal menu by pressing K2 key
3) Comfi rm by K4 the E-Seal reading.
Now the fi rst Record is showed on the display (see fi gure 1). To increase the record index press K4; to decrease the
record index press K3. The following pictures are only an example of E-Seal records because every single device could
have a diff erent records sequence.
MAIN DISPLAY PRINTED REPORT DESCRIPTION EVENTS
K-Cons
K-CONS
Constant “K” calibra on Autotest
A.DEFL
A.DEFL
A er checksum error with black key inserted Autodefault
TARIFF
TARIFF
Tariff Programming Tariff
CLOCK
CLOCK
Clock se ng Clock
SYN.CL
SYN.CL
Clock +/- 2’ syncro Syncro Clock
TICKET
TICKET
cket heading programming Header Ticket
M.E.S.
M.E.S.
Mul extra-charge system programming Mes
CL.MEM
CL.MEM
Sta s cal Memory block reset (block 2) Clear memo
DEFAUL
DEFAUL
By manual opera on General Default
LB.RES
LB.RES
Long Buff er Memory Reset Long Buff er Reset
BIOS
BIOS
Firmware changed Bios Change
LIGHTS
LIGHTS
Taxi Roof Lights Test Light Test Result
4) By pressing K4 the E-Seal menu has two op ons depend-
ing on the event type. In that case showing Bios event type
by pressing K4 we will see the Bios Checksum Programmed.
By pressing again K4 we will go to the next event type.
5) In that event type by pressing K4 we will go to the next
event type (DEFAUL).
6) By pressing K3 we will go to the previous event type
(LB. RES)
(fi gure 1)
7) Press OP to exit and return to main screen
Note:
At any inde
x posi on by pressing K1 the E-Seal counters report will be printed
At any index posi on by pressing OP the taximeter will come back to
For Hire posi on
1) Modifi ed Record Number
2) Event type
3) Event Modifi ca on Date
4) Event Modifi ca on Time
5) Event Value
BIOS 0
operator.IDevent type
E-SEAL
BIOS 23241
event type
10.50
LB.RES 0
operator.IDevent type
DEFAUL 0
operator.IDevent type
LB.RES 0
operator.IDevent type