EasyManuals Logo

Digitax M1 mdt User Manual

Digitax M1 mdt
84 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #32 background image
The information contained here are property of DIGITAX Automotive Electronics Italy, and extremely con dential. Any disclosure, copying, distribution to third
party
is strictly prohibited.
32
The “ProgDate”
“Progdate” is a kind of taximeter programming based on me events. This means that is possible to de ne a period
of me during which a par cular ac on is performed by the taximeter.
The M1 MDT meter can be programmed with up to 50 Progdate records, every one with di erent ac va on mes or
ac on to be performed.
The ac va on date of every record can be one of the following:
from a start date to an end date
a speci c date of every year
a speci c day of every month
some speci c days of every week
It is also possible to specify a me period during the ac va on days, de ned by a start me and an end me (for
example from 12.00 to 15.00 to iden fy the peak hour).
When the Progdate is ac vated, a programmed ac on is performed by the meter. Some are pre-de ned, with xed
meaning, some other are referred to the M1 MDT programming ques ons. These are the possible ac ons codes, with
their meaning:
Night Time = ProgDate 1
Holiday Time = ProgDate 2
ac ons iden ed by Ques on 63 to Ques on 73 of the meter programming. = ProgDate 3
ac ons iden ed by Ques on 74 to Ques on 84 of the meter programming. = ProgDate 4
ac ons iden ed by Ques on 85 to Ques on 95 of the meter programming. = ProgDate 5
ac ons iden ed by Ques on 96 to Ques on 106 of the meter programming. = ProgDate 6
ac ons iden ed by Ques on 107 to Ques on 117 of the meter programming. = ProgDate 7
ac ons iden ed by Ques on 118 to Ques on 128 of the meter programming. = ProgDate 8
Maintenance Expired = ProgDate 14
Winter / Summer Time = ProgDate 15
Dimmer Time = ProgDate 16
logo to print (only with Printer Due / Tre and speci c rmware releases) = ProgDated 17 to 28
Ac ons related to the programming Ques ons can be an absolute or rela ve block jump, a cost percentage or delta
di erence in the costs, or other similar ac ons.
Please refer to the M1 MDT manual (Programming parameters chapter) for a detailed explana on of the e ects of
every speci c one.
It is possible to program a tari in advance, by wri ng its parameters in a not ac ve block of the tari grid.
This pre-programmed tari can be ac vated at the me and date speci ed by a progdate, using the absolute block
jump ac on or rela ve block jump ac on, so that the execu on could jump to the block of the pre-programmed tari .

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Digitax M1 mdt and is the answer not in the manual?

Digitax M1 mdt Specifications

General IconGeneral
BrandDigitax
ModelM1 mdt
CategoryAutomobile Accessories
LanguageEnglish

Related product manuals