The Tariff
General Descrip on
Here follows an example of an easy tariff that uses two Blocks to calculate two diff erent tariff amounts.
In the subscribed example there are two tariff s that diff er for the ini al drop value distance (Parameter n. 11).
The Block 1 has been programmed with an Ini al Drop Value distance of 1000, the Block 2 with a value distance of 2000.
To pass from Block 1 to Block 2 must be pressed K1 bu on. To do it program the Parameter n. 13 of the Block n. 1 with a
value of 2 (se ng value of 2 means > go to Block 2 ).
To go back to Block 1, set in Parameter n. 13 of Block 2 the value of 1.
With this procedure it is possible to move from Block 1 to Block 2 and change the bander value by pressing K1 bu on.
- Power on the taximeter. By default all the parameters programmed in Block 0 get loaded in the Working Block.
- Press OP bu on to pass in Hired posi on. Now Block 1 gets loaded in the Working Block upda ng the changed param-
eters values (Parameter 11 = 0 > 11).
PS: The parameter 15 defi ne the start fare block. This is the block loaded when OP bu on is pressed to pass from For Hire
to Hired posi on.
Working
Block
Param.001
.
.
.
.
.
Param.429
Working
Block
Param.001
.
.
P.340
.
Param.429
Working
Block
Param.001
.
.
.
.
Param.429
Working
Block
Param.001
.
P.340*
.
Param.429
Block 0
Param.001
.
.
.
.
Param.429
Easy
Tariff
Amount
Power
On
Power
On
Power
On
Final
Tariff
Amount
Complex
Tariff
Amount
*= Modifi ed Parameter
Block 0
P.001.
.
.
.
P.015=1
.
.
.
Param.429
Wk.Block
P.001.
.
.
.
P.015=1
.
.
.
Param.429
Block 1
P.001.
.
P.011=1000
.
P.013=2
.
.
.
Param.429
Wk.Block
P.001.
.
P.011=1000
.
P.013=2
.
.
.
Param.429
Block 2
P.001.
.
P.011=2000
.
P.013=2
.
.
.
Param.429
Wk.Block
P.001.
.
P.011=2000
.
P.013=2
.
.
.
Param.429
The taximeter calculates the tariff thanks to the interac on of 429 programmable parameters.
They work into a block. The M1 MDT have 63 parameters blocks that can be programmed to generate even the most
complex tariff . Two blocks are very par cular: Block 0 and the Working
Block.
The Block 0 is the StartUp block that loads per default all the 429 pa-
rameters in the Working Block when the taximeter starts up. In
a simple tariff calcula on is suffi cient to use only the Block 0 to
calculate the amount.
The “Working Block” (not visible by the user) is the opera ve
block that makes the fi nal tariff calcula on.
In a simple tariff , it is ge ng charged by Block 0 with his 429
default programmed parameters. It calculates the fi nal amount.
To calculate a more complex tariff it is necessary
to use, in addi on to Block 0 , other programmed
blocks of parameters.
Their content replace, at the programmed event
(Prog.Date, Key press OP, K1, K2 etc.),
the relevant parameters of the Working Block.
Every new modifi ed parameter value in a Block
will replace the old one in the Working Block up-
da ng the tariff .
Example
For Hire Hired Hired