Automatic Defrost Function
The HiPro electronic also regulates the automatic defrosting of the
refrigerator. When the plug has been stuck to the socket the running time of
the refrigerator up to the first defrosting is 39 hours For all
models the defrosting takes 2 hours. Then the refrigerator works 22
hours and afterwards defrosts 2 hours.
Therefor the starting of the refrigerators determines the time of defrosting.
For example: Starting at 7.00h = first defrosting 22.00h (next day).
Cooling unit check
In order to carry out the check of the cooling unit, e.g. a leak within the
cooling circle, the temperature difference at the evaporator sensor is
determined every 40 minutes. If, after finishing the defrost phase the fridge
does not reach a cool-down of 4K within 40 min, a system error exists,
and the fridge is switched off.
The system error is saved in the EEPROM and indicated by permanent
flashing of the indoor lighting as well as the REDDOT_LED with 8 Hz.
System errors are:
- Leak / clogging of the cooling unit
- the HiPro is not balanced
- heating element defective
In service-case the cooling unit is not changeable. You have to
install a complete new HiPro miniBar!
Heating Shell
After max. 5 seconds, the heating element is driven with supply voltage and
works for 20 seconds. This cycle is repeated for 45 minutes. After this the
electronic controls the prefixed temperature.
Please see also point 5.0, page 5
29
19.4
S
TT
TT
TT
S
39h
19.5
19.6

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Dometic RH330LD and is the answer not in the manual?

Dometic RH330LD Specifications

General IconGeneral
BrandDometic
ModelRH330LD
CategoryRefrigerator
LanguageEnglish

Related product manuals