Every 40 Hours
Document ID: OMM-00144-L VUTEk 3r & 5r Series Maintenance Guide 44
3. Turn grease gun nozzle 1/2 turn to open nozzle.
4. Attach grease gun to grease fitting and turn grease gun nozzle 1/2 turn to tighten the grease gun nozzle; this closes the nozzle
onto the fitting to reduce grease overflow.
5. Apply 3 pumps of grease to each bearing, or fewer pumps if grease can be seen overflowing.
6. Loosen the grease gun nozzle 1/2 turn to remove the grease gun nozzle from the fitting and wipe up any grease overflow.
Caution: Do not over-loosen or remove nozzle tip.
Figure 6-10 Preparing grease gun nozzle
Figure 6-11 Applying grease