04/2011 - Art. Nr. 4200 1037 0000A28
Commissioning
Adjustment data
The adjustment values above are guide
values and facilitate commissioning.
The factory settings are in bold set
against a grey background The final
settings are essential in ensuring that
the burner functions as well as possible
The VG2.200 settings apply for
burners with the orifice plate
installed (see page 30).
If the orifice plate is removed, the
burner must be completely read-
justed.
Setting the gas pressure switch
• Remove the transparent cover.
• Provisionally set to 5mbar.
Setting the air pressure switch
• Remove the transparent cover.
• Provisionally set to 1 mbar.