16
fig.c1
fig.c2
fig.c3
Security
C) Circulation (fig. c1) :
check the heart beat (fig. c1)
in the absence of a heart beat, start cardiac massage (fig. c2)
press the sternum every 1.5 - 2 seconds
if there is one first aider, perform 15 compressions in about 80 seconds and 2 quick
respirations.
if there are two first aiders, perform 5 compressions in about 60 seconds and one
respiration (fig. c3)
WARNING :
Do not interrupt the rythm of cardiac compression when the second person is perfor-
ming artificial respiration.
3.2.2.2 If the casualty is conscious
cover the casualty with a blanket
ensure the casualty is calm
loosen clothing and lay the casualty flat
WARNING:
IN ANY CASE CALL A DOCTOR IMMEDIATELY
3.3 Station features
3.3.1 Environment features
To be able to operate freely on the equipment and be able to make installation or
maintenance it is necessary to maintain a minimum distance from the walls on each
side of the machine.
The room must be equipped with an adequate fresh air and filtered from dust, with
adequate capacity with the characteristics of the equipment working in space.
The output exhaust air must be conveyed directly to the outside.
If the size or the duct length are such that assume a significant air flow drop it is neces-
sary to add an extraction device.
At the conveyor exit shall be provided devices against intrusion (compared to insects
or other animals) and precautions should be taken to prevent entry of liquids or other
materials.
The device can operate properly if the temperature is between -5 °C to +45 °C, with
relative humidity to 95%, non-condensing to +40 °C.
3.3.2 Wiring features
The mains system shall be in accordance with all current rules. The power supply should
enable to provide adequate power in accordance with regulations of the installation
country about the service quality of electricity supply.
It’s recommended the use of a network isolating transformer and of an energy reduc-
tion network for high voltage discharges.
Provide a protected switchgear (circuit breaker or fuse) with breaking and flow properly
related to the device absorption characteristics.
Use cables properly sized related to current input.