Reference Manual
00809-0100-4853, Rev AB
Configuration
January 2017
3
Configuration
Section 2 Configuration
Flow configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 4
Variable configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 10
Device configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 13
Device capabilities . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 14
Node address . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 15
Block instantiation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . page 16
2.1 Section overview
This section contains information for the flow and device configuration of the Rosemount
3051S
MultiVariable
FOUNDATION
Fieldbus Transmitter (3051SMV). Each FOUNDATION Fieldbus host or
configuration tool has different ways of displaying and performing operations. Some hosts will use
Device Descriptions (DD) and DD methods to complete device configuration and will display data
consistently across platforms.
The DD can be found on the FieldComm Group website at FieldCommGroup.org
. There is no
requirement that a host or configuration tool support the features in the DD. For DeltaV
users, the DD
can be found at EasyDeltaV.com
. This section will describe how to use the basic methods.
2.2 Safety messages
Instructions and procedures in this section may require special precautions to ensure the safety of the
personnel performing the operations. Information that raises potential safety issues is indicated by a
warning symbol ( ). Refer to the following safety messages before performing an operation.
Explosions could result in death or serious injury.
Do not remove the transmitter cover in explosive atmospheres when the circuit is live.
Before connecting an Emerson
Field Communicator in an explosive atmosphere, make sure the
instruments in the segment are installed in accordance with intrinsically safe or non-incendive field
wiring practices.
Verify the operating atmosphere of the transmitter is consistent with the appropriate hazardous
locations certifications.
Both transmitter covers must be fully engaged to meet flameproof/explosion-proof requirements.
Failure to follow these installation guidelines could result in death or serious injury.
Make sure only qualified personnel perform the installation.
Electrical shock could cause death or serious injury.
If the sensor is installed in a high-voltage environment and a fault or installation error occurs, high
voltage may be present on the transmitter leads and terminals.
Use extreme caution when making contact with the leads and terminals.