Section 2: Actuator Disassembly
Actuator Disassembly
2.5.10 Remove at head screw (20 - 10 - 330) from the manifold (20 - 10 - 10).
2.5.11 Remove disc, control valve (20 - 10 - 290) from the manifold (20 - 10 - 10).
2.5.12 Remove seal O-ring (20 - 20 - 40) from the manifold (20 - 10 - 10).
2.5.13 Remove seal O-ring (20 - 20 - 90) and backup ring (20 - 20 - 100) from back plate,
control valve (20 - 10 - 320).
2.5.14 Remove seal O-ring (20 - 20 - 110) and backup ring (20 - 20 - 120) from piston,
control valve (20 - 10 - 310).
2.5.15 Remove seal O-ring (20 - 20 - 40) and backup ring (20 - 20 - 50) from stem,
control valve (20 - 10 - 280).
2.5.16 Remove pump rod (20 - 10 - 50) from pump cylinder (20 - 10 - 20).
2.5.17 Remove rod wiper (20 - 20 - 20), rod bushing (20 - 20 - 30) and polypak seal (20 -
20 - 10) from the pump cylinder (20 - 10 - 20) bore.
2.5.18 Remove retainer ring (20 - 10 - 80) from manifold (20 - 10 - 10).
2.5.19 Use 1/4 - 20 UNC socket cap screw (20 - 10 - 240) as provided in service kit to
remove the pin, cylinder (20 - 10 - 60) from the manifold (20 - 10 - 10). Remove
the pump cylinder (20 - 10 - 20).
2.5.20 Remove seal O-ring (20 - 20 - 40) and backup ring (20 - 20 - 50) from the pin,
cylinder (20-10-60).
2.5.21 Remove seal O-ring (20 - 20 - 60) and backup ring (20 - 20 - 70) from the pump
cylinder (20 - 10 -20).
2.6 M18 Reservoir Disassembly
2.6.1 Remove acorn nut (10 - 50), counter sink washer (10 - 60) and thread seal (10 - 70)
from the end cap, upper (10 - 10).
2.6.2 Remove end cap, bottom (10 - 40) by tapping from the open end of center
bar (10 - 30).
2.6.3 Remove seal O-ring (10 - 100) from the end cap, bottom (10 - 40).
2.6.4 Remove end cap, upper (10 - 10) from the reservoir cylinder (10 - 20).
2.6.5 Remove seal O-ring (10 - 100) from the end cap, upper (10 - 10).

Table of Contents

Other manuals for Emerson Bettis G4 Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Emerson Bettis G4 Series and is the answer not in the manual?

Emerson Bettis G4 Series Specifications

General IconGeneral
BrandEmerson
ModelBettis G4 Series
CategoryController
LanguageEnglish

Related product manuals