62
5.2 Solutions
Fault
Solution
Battery over
voltage
Check whether the battery voltage is too high and disconnect
the PV modules.
Battery over
discharge
Waiting for the battery voltage to resume to or above LVR
point (low voltage reconnect voltage) or changing the power
supply method.
Battery
overheating
When the battery temperature declines to the overheating
recovery temperature or lower, the inverter/charger will
resume working.
Device
overheating
When the device temperature declines to the overheating
recovery temperature or lower, the inverter/charger will
resume working.
Output overload
Please reduce the number of AC loads.
Restart the device to recover the load output.
Output short
circuit
Check carefully loads connection, clear the fault.
Restart the device to recover the load output.