EasyManuals Logo
Home>Ephoca>Heat Pump>HPAC 2.0

Ephoca HPAC 2.0 Installation Manual

Default Icon
26 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #24 background imageLoading...
Page #24 background image
24
LCDI POWER CORD CONNECTION
HPAC 2.0 is equipped with a power cord and LCDI (Leakage Current Detection Interrupter) power cord. If using a power
socket near the unit, simply insert the plug.
Before connecting the unit check that:
The power supply voltage and frequency values comply with the data plate of the appliance.
The power outlet is grounded connection and that it is sized for the maximum wattage of the conditioner
(minimum cable section equal to 1.5 mm2).
Power is only supplied using a suitable socket through the supplied plug.
The power supply is provided with suitable protections against overloads and/or short-circuits (using the correctly
sized Time delay fuse or other equivalent devices is recommended).
WARNING
ELECTRICAL SHOCK HAZARD
If the supply cable is replaced, this must be done exclusively by
the technical assistance service or by authorized personnel and in
compliance with current national regulations. Improper wiring may
result in property damage, injury or death.

Other manuals for Ephoca HPAC 2.0

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Ephoca HPAC 2.0 and is the answer not in the manual?

Ephoca HPAC 2.0 Specifications

General IconGeneral
BrandEphoca
ModelHPAC 2.0
CategoryHeat Pump
LanguageEnglish