Issue
10.03.B
XT Series DISK RECORDER
Version 10.03 - Hardware Technical Reference
EVS Broadcast Equipment SA
July 2010
8
Class of equipment: Class 1 equipment (EN60950 § 1.2.5): electric shock
protection by basic insulation and protective earth.
Rated voltage: 110 to 240Vac (single phase)
Rated frequency: 50-60 Hz
Related Current: 10 A (100 to 120 Vac range) 5 A (220 to 240 Vac range)
Input connector: CEE22/IEC 320 3-pin male receptacle
Environmental Conditions
The equipment should be kept in the following environmental conditions:
Temperature: 0°C to +40°C (32°F to 104°F) ambient with free air flow
Relative humidity: 0% to 90% (non-condensing)
Cooling requirements: Forced air cooling air flow from front to back
Handling/movement: Designed for fixed use when in operation
Storage and transportation temperature: 0°C to +70°C (32°F to 158°F)
Storage and transportation relative humidity: 0% to 90% (non-condensing)
HOT SWAP
This equipment is equipped with AUTOSWITCH and hot-swappable power supply.
Connection to supply: Pluggable equipment Type A (EN60950 §1.2.5): Equipment
which is intended for connection to the building power supply wiring via a non-
industrial plug and socket-outlet or a non-industrial appliance coupler or both.
Correct mains polarity must always be observed. Do not use reversible power
plugs with this equipment.
Class of equipment: Class 1 equipment (EN60950 § 1.2.5): electric shock
protection by basic insulation and protective earth.
Rated voltage: 115 to 240Vac (single phase)
Rated frequency: 47-63 Hz
Related Current: 8 A (100 to 120 Vac range) 4 A (220 to 240 Vac range)
Input connector: CEE22/IEC 320 3-pin male receptacle
Environmental Conditions
Temperature: 0°C to + 50°C (32°F to 104°F) ambient with free air flow
Relative humidity: 0% to 90% (non-condensing)
Cooling requirements: Forced air cooling air flow from front to back
Handling/movement: Designed for fixed use when in operation
Storage and transportation temperature: 0°C to +70°C (32°F to 158°F)
Storage and transportation relative humidity: 0% to 90% (non-condensing)