USER PARAMETERS
40
Chapter8
Press button 1 to escape.
Nota bene: The relative indicator light on the control board will switch on when the weekly programmer is
active (see display table description).
TO DEACTIVATE THE WEEKLY PROGRAMMER enter user programming by pressing key 3 and holding it
down press key 5. Shift using button 5 until “CHRONO” appears on display D1 and set“OFF” in display D2
using keys 2 and 3. Successively press key 1 to con rm and escape.
The manual controls, from the display or remote control, always remain priority with respect to
programming.
PELLET FEED ADJUSTMENT
In the case of functioning problems owing to the quantity of pellets, adjust pellet feeding directly from the
control board.
The problems correlated to the amount of fuel can be divided into 2 categories:
LACK OF FUEL:1.
the stove can never develop a suitable ame, tending to remain very low even at high powers
at minimum power the stove tends to almost switch o taking the stove into “ NO PELL” alarm
conditions.
when the stove displays the “ NO PELL” alarm, there may be non-burned pellets inside the pot
EXCESS FUEL:2.
it develops a very high ame even at low powers
the brazier tends to become encrusted, blocking the holes for air intake due to the excessive pellet
feed, as it is only burned partially
N.B. If the problem occurs after only a few months working, check that routine cleaning stated in the
booklet, has been carried out correctly.
The regulation to be performed is a percentage. Therefore a modi cation of this parameter will lead to a
proportional variation of all feeding speeds.
To access the percentage adjustment of pellet feeding, enter the user programming by pressing key 3 and,
holding this down, press key 5.
At this point use key 5 to move within the menu until “UT F” appears on display D2.
If, inadvertently, progress is made beyond this parameter, exit using key 1 and repeat the operation.
The value “00”will appear on display D1: keys 2 and 3 can be used to adjust the percentage increase/
decrease desired by 5 points per time (the parameter can be varied with a maximum travel from –50 to
+50).