SUPPLEMENTARY OPERATING MANUAL 2
2-
2
05-19-06 CDP-01 Figure Sheet 1-900
Input Matrix - External Control (X7)
Inputs CDP-01
Modes
15 14 13 12 11 10
Oscillator ON - - - - - H
Oscillator OFF - - - - - L
Automatic (seek, then guide) - H H L L -
Auto Permissive (seek only) - L H L L -
Manual (both drives) - - L L H -
Retract Sensor / Center Mandrel - L L H L -
Center Mandrel Only - L H H L -
Retract Sensor Only - H L H L -
Jog Mandrel Left L H L H H -
Jog Mandrel Right H L L H H -
Jog Sensor Out L H H L H -
Jog Sensor In H L H L H -
L = Low level
H = High level
- = any
Network Traffic
The table below shows the configuration mapping for data traveling from a Network to FifeNet.
Network to FifeNet Data
Scheduled Data Word Source
1
Data Type
2
Variable Description
0 WORD Device 1
Command
3
Network commands sent to the
CDP-01. Simulated key presses, etc.
The table below shows the configuration mapping for data traveling from FifeNet to a Network.
FifeNet to Network Data
Scheduled Data Word Source
1
Data Type
2
Variable Description
0 WORD Reserved Reserved
1 and 2 DWORD Reserved Reserved
3
4
DWORD
Panel Data 0
Panel Data 1
CDP-01 LED panel data
5 WORD Device 1 Response
3
CDP-01 Fife Network responses
6 INT Edge Left Sensor Signal
7 INT Edge Right Sensor Signal
8 INT Line Center Sensor Signal
9 INT Line Edge Sensor Signal
10 WORD SM Command Feedback Reserved for State Machine control.
11 WORD SM Status Feedback Reserved for State Machine control.
12 WORD Common Status Register CDP-01 status
13 WORD Key pressed Current key pressed on CDP-01 panel.
14 WORD Drive 2 Operation Mode Drive 2 mode status
15 WORD Drive 2 Sensor Mode Drive 2 sensor status
16 WORD Drive 2 Fault Register Drive 2 fault status
17 WORD Drive 2 Alarm Register Drive 2 alarm status
18 WORD Drive 2 Operation Mode Drive 2 mode status
19 WORD Drive 2 Sensor Mode Drive 2 sensor status
20 WORD Drive 2 Fault Register Drive 2 fault status
21 WORD Drive 2 Alarm Register Drive 2 alarm status
1 = All data words are 16 bits.
2 Data Types:
* INT 16-bit signed value in the range of –32,768 to +32,767.
* WORD 16-bit unsigned value in the range of 0 to 65,535.
* DWORD 32-bit unsigned value in the range of 0 to 4,294,967,295.
3 = Commands to the CDP-01.