SUPPLEMENTARY OPERATING MANUAL 2
2-
1
05-19-06 CDP-01 Figure Sheet 1-900
OVERVIEW OF FUNCTION
Operator Control Options
The CDP-01 signal amplifier can be operated by way of the CDP-01 control panel (internal operation)
for setup purposes only. For normal operational control, the parallel port (external operation) must be
used. Control is to be supplied from a remote control panel or programmable logic controller.
The symbols below are used for the various operator control options in the following:
Internal operation
External operation
Special Features of External Control
When the operation modes are being controlled via
external control, the Automatic, Servo-Center, Manual
keys of the CDP-01 control panel are disabled.
If the cable to the parallel port ( -X7 ) of the CDP-01 is
disconnected, the operation mode is changed to Manual
mode.