SUPPLEMENTARY OPERATING MANUAL 2
2-
10
05-19-06 CDP-01 Figure Sheet 1-900
Start-up / Guiding Sensor Calibration (Reference Channel)
The following procedure must be performed while in Manual mode with all parallel inputs low.
Select Drive 3 by pressing key 20.
Press the Sensor key repeatedly until LED 9 is lit.
Press and hold the Left or Right Jog key to retract the
sensor until the web is completely out of the sensor
field of view.
Press the Setup key.
Press the Sensor key.
Press the F1 key.
Press and hold the Left or Right Jog key until the web
completely covers the sensor field of view.
Press the F2 key.
Press the Automatic key to store the settings.
or
Press the Manual key to abort the procedure.