EasyManuals Logo
Home>FLIR>Thermographic Cameras>A6000 Series

FLIR A6000 Series User Manual

FLIR A6000 Series
86 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #61 background imageLoading...
Page #61 background image
5 Camera Controller
A6000 and A8500 Series User’s Manual
61
to the A/D stages, there is no detrimental effect on performance from the use of the global gain and
offset controls.
Use of global gain and offset to linearize the camera
5.7.2 Analog Settings
These controls are set at the factory for the focal plane array in the camera. The controls are intended
only for the power user who should consult with FLIR application support before changing these
values.
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
0
2000
4000
6000
8000
10000
12000
14000
16000
18000
Background flux
Typical camera
setup, gain = 1
offset = 0
As linearized
desired operating range