Operation
12
12.10 Connecting the camera to a computer
12.10.1 General
You can connect the camera to a computer, using the USB cable. Once connected, you
can move the images from the camera’s archive to the computer. You can also import
the images into the FLIR Tools software. A download card for FLIR Tools is included in
the transport case.
12.10.2 Procedure (FLIR K45, FLIR K55)
Follow this procedure:
1. Fold up the rubber cover at the top of the camera.
2. Hold the metal ring firmly.
3. Rotate the ring about 90° counter-clockwise.
4. Pull out the plastic insert.
CAUTION
The plastic insert has an O-ring seal. Do not damage the O-ring seal.