EasyManuals Logo
Home>Fluke>Measuring Instruments>OptiView II Series

Fluke OptiView II Series User Manual

Fluke OptiView II Series
60 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #59 background imageLoading...
Page #59 background image
Integrated Network Analyzer
Specifications
51
Characteristic Impedance
50 to 150 Ohms, cables 3-5 m (10-16 ft.) +/- (5 Ohms +10%)
50 to 150 Ohms, cables >5 m (16 ft.) +/- (5 Ohms +5%)
Resolution: 1 Ohm
Receive Level
100 to 5000mVp-p, +/- 5%
Resolution: 10mV
Datalink Signal
500mVp-p to 4000mVp-p
Measuring Terminated Cables
Cable Test analyzes individual twisted-pairs of a cable that are terminated into
most equipment vendors’ Ethernet ports such as on a hub, switch or NIC.
All cable tests other than wiremap and office locator ID are operational in the
presence of datalink signal.
Fault Tolerance
The RJ-45 10/100BASE-T Ethernet connection on the analyzer is designed to
withstand a maximum of 100 volts.
GBIC Identification
Identifies and operates with the following GBIC module types per SFF Document
Number SFF-8053, Gigabit Interface Converter, Rev. 5.4: LX (1300nm), SX
(850nm).
WireView
TM
Compatibility
Detects combinations of shorts, opens, and connector miswires. Compatible with
wire mapper/office locators (officially called WireView
TM
, also called wire map
adapter and office locator) labeled for Fluke Networks OptiView
TM
analyzer.

Table of Contents