AP-6
APPENDIX 4 ALERTS & INDICATIONS
Alerts
* The number of digits shown depends on the setting of [ALERT MODE] (in the installation menu).
Indications
Alert
No.
Title
Priority/
Category
Instance Message Remedy
0211003 System
failure
Caution/B 1 Stop speed
measurement
for safety.
Have a qualified technician
check the set.
0211003 System
failure
Caution/B 2 Communica-
tion error with
Transceiver.
Check the connections be-
tween the distributor unit and
the transceiver unit. If the
connections are normal, have
a qualified technician check
the set.
0211006 Uncertain
STW
Caution/B — Speed reliabil-
ity is low.
The condition can be tem-
porary: Air bubbles, etc.
can temporarily interrupt
both transmission and re-
ception.
As a remedy, change the
speed source. If the alert re-
occurs, have a qualified tech-
nician check the set.
Title Message Meaning Remedy
DIST COM Error Communication error with
Distributor.
Cannot communicate with
the Distributor Unit.
Check connections
between the display
unit and the distribu-
tor unit.
DISP 12V Error Display 12 volt error. 12 V power in the Display
Unit is not within the spec-
ifications.
Have a qualified tech-
nician check the set.
TVCR 5V Error Transceiver 5 volt error. 5 V power in the Trans-
ceiver Unit is not within the
specifications.
TVCR 12V(D)
Error
TCVR 12 volt digital error. 12 V digital power in the
Transceiver Unit is not
within the specifications.
TVCR 12V(A)
Error
TCVR 12 volt analog error. 5 V analog power in the
Transceiver Unit is not
within the specifications.
TCVR 24V Error Transceiver 24 volt error. 24 V power in the Trans-
ceiver Unit is not within the
specifications.
TVCR TEMP
Error
Transceiver TEMP error. Transceiver temperature
is too high.
Turn off the transceiv-
er. Wait 2-3 minutes,
then power the unit. If
the error re-occurs,
have a qualified tech-
nician check the set.