Programming the Panel
19
Settings in tier 2 menus can also be accessed by entering shortcut numbers. See the section, “Pro-
gramming Tier 2 Menu Items” for complete details.
Programming Tier 1 Menu Items
This section guides you through programming tier 1 menu items as they appear in sequence. The
exact order you need to follow will depend on whether you’re installing a new system or chang-
ing the programming of an existing system.
Programming Tier 2 Menu Items
This section guides you through programming tier 2 menu items as they appear in sequence.
Each menu on tier 2 represents a group of settings related to the menu name. Refer to Figure 22
for the menus available on tier 2.
Demo Kit Mode
System Programming (Default = Off)
This setting determines whether the panel is used for a standard installation
(off) or as a demo kit (on). Turning on this feature and performing a memory
clear changes the following settings:
System Master Code = 1234
User Code 00 = 1001 (standard user code capabilities)
User Code 01 = 1002 (standard user code capabilities, bypass sensors)
User Code 04 = 1122 (standard user code capabilities, system tests)
Zone 1 (hardwire) = Group 10, Front Door
Zone 2 (hardwire) = Group 13, Bedroom Window
Zone 3 (hardwire) = Group 17, Living Room PIR
Zone 4 (hardwire) = Group 01, Panic
Zone 5 (wireless) = Group 01, Keychain Touchpad
Zone 6 (wireless) = Group 13, Kitchen Window
COMM FAILURE = off
Entry Delay = 8 seconds
Exit Delay = 8 seconds
Extended Delay = 1 minute
Siren Timeout = 2 minutes
Status Beeps = on (all touchpads)
Central Station Reporting = sensors learned into groups 01 and 03,
Duress code use, and phone test (
8 + CODE + 2)
¾
To turn Demo Kit Mode On or Off:
1. With the display showing DEMO KIT OFF/ON
(current setting), press 1 (off) or 2 (on).
The display flashes the entered setting.
2. Press
ƒ and the display shows DEMO KIT
OFF/ON
(new setting).
3. Clear panel memory to enable the demo kit
mode (see next menu).
Clear Memory (System Programming)
System Programming
Clearing memory with the Dealer Code deletes all existing
programming except the Dealer Code.
If the Dealer Code HAS NOT been set, clearing the memory
with the Installer Code deletes all existing programming.
If the Dealer Code HAS been set, clearing the memory with
the Installer Code deletes all existing programming except:
Dealer Code
Downloader Code
CS Phone 1
CS Phone 2
¾
To clear Panel Memory:
1. With the system in program mode, press B until the display
shows
CLEAR MEMORY.
2. Press
ƒ and the display shows ENTER CODE TO CLEAR MEM-
ORY.
3. Enter the 4-digit installer
CODE (or dealer if
programmed) +
ƒ.
After about one second, the system restarts and the panel scans
the bus to learn all bus devices. If the system doesn’t respond as
described, repeat step 3.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE 60-806-95R-16Z - Security Concord Express System Control Panel and is the answer not in the manual?

GE 60-806-95R-16Z - Security Concord Express System Control Panel Specifications

General IconGeneral
BrandGE
Model60-806-95R-16Z - Security Concord Express System Control Panel
CategorySecurity System
LanguageEnglish

Related product manuals