FUNCTION DISPLAY SETTING DESCRIPTION SETTING
6-24
Setting Running
Stopping
When speed is controlled from KEYPAD (00=0),
displays changes to indication below if speed is changed
Unit
0 Output Frequency Set frequency Setting frequency Hz
1 Output current Setting frequency A, Hz
2 Output voltage Setting frequency V, Hz
3 Motor Speed
(w/o slip)
Set Motor Speed
(w/o slip)
Setting Motor Speed
(w/o slip)
r/min
4 Line Speed Set Line Speed Setting line speed m/min
5 Machine rotating Speed Set Machine Rotating speed Setting Machine Rotating Speed r/min
6 Torque Limiter/Driving Setting Frequency %, Hz
7 Torque Limiter/Braking Setting Frequency %, Hz
8 Calculated torque Setting Frequency %, Hz
LED & LCD MONITOR
* 61 LED MNTR 1 LED MONITOR SELECTION #1 0
Setting from 0 to 8 for a total of nine (9)
selectable indicating modes. See table below:
* 62 LED MNTR 2
LED MONITOR SELECTION #2 0
This setting determines the LED display
in the STOP Mode of operation.
0:
Setting value
1:
Output value
* 63 SPEED COEF
MOTOR POLE SPEED CONVERSION COEFFICIENT 0.01
The LED display for machine speed and line speed
can be changed by setting this Function Code.
Output Hz indication multiplied by this value
will be shown on the LED display. Adjustable
from 0 to 200.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com