NX-4 Control
Page 31
LOC PG DESCRIPTION DEFAULT DATA
64 22
AUXILIARY 2 0-0 _ _
65 22 KEYPAD PANIC 0-2 _ _
66 22 KEYPAD MULTIPLE CODE ENTRY TAMPER 0-0 _ _
67 22 BOX TAMPER / BOX TAMPER RESTORE 0-0-0-0 _ _ _ _
68 23 AC FAIL / AC RESTORE 0-0-0-0 _ _ _ _
69 23 LOW BATTERY / LOW BATTERY RESTORE 0-0-0-0 _ _ _ _
70 23 POWER SHORT / POWER SHORT RESTORE 0-0-0-0 _ _ _ _
71 23 BELL TAMPER / BELL TAMPER RESTORE 0-0-0-0 _ _ _ _
74 23 EXPANDER TROUBLE / EXPANDER TROUBLE RESTORE 0-0-0-0 _ _ _ _
75 23 FAILURE TO COMMUNICATE 0-0 _ _
76 23 LOG FULL COMMUNICATOR CODE 0-0 _ _
77 23 OPENING CODE COMMUNICATOR CODE 11 _
78 23 CLOSING COMMUNICATOR CODE 12 _
79 23 AUTOTEST COMMUNICATOR CODE 0-0 _ _
80 23 RECENT CLOSING AND EXIT ERROR 0-0 _ _
81 24 START PROGRAMMING / END PROGRAMMING 0-0-0-0 _ _ _ _
82 24 END DOWNLOAD 0-0-0-0 _ _ _ _
83 24 CANCEL COMMUNICATOR CODE 0 _
CUSTOMIZING ZONE TYPES (GROUPS)
These locations are considered advanced programming and should only be changed with a thorough
understanding of the
operation of each bit. These locations are used to design or customize zones when the Standard Zones Types in Table 2.1
on page 25 do not fit your needs.
110
24
GROUP 1 ALARM EVENT CODE
8
_
GROUP 1 CHARACTERISTIC SELECT
Segment #1 (Circle numbers to program)
1
2
3
4
Fire (enable for fire zone)
24 Hour (enable for non-fire 24 hour
zone)
Reserved
Follower (enable for bur
g
zones that are
instant during non-entry times)
5
6
7
8
Delay 1 zone (enable to follow Timer 1 Entry/Exit
times)
Delay 2 zone (enable to follow Timer 1 Entry/Exit
times)
Interior (Enable for auto bypass or stay arming)
Local Only (enable if zone is not to be reported)
Segment #2 (Circle numbers to program)
1
2
3
4
Keypad audible on alarm.
Yelping siren on alarm.
Temporal siren on alarm.
Chime.
5
6
7
8
Bypassable.
Group Shunt.
Force Armable.
Entry Guard.
Segment #3 (Circle numbers to program)
111
24
1
2
3
4
RESERVED.
Double End of Line Tamper zone.
Trouble zone (Day zone).
Cross Zone.
5
6
7
8
Dialer Delay zone.
Swinger zone.
Restore reporting.
Listen-In.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-4 and is the answer not in the manual?

GE NetworX NX-4 Specifications

Power IconPower
operating power16.5 VAC 25, 40, or 50 VA Transformer
auxiliary power with 25 VA transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA transformer12 VDC Regulated 1 AMP
Operating Environment IconOperating Environment
loop resistance300 Ohms Maximum
loop response500mS
operating temperature32 to 120 degrees F
Weight and Dimensions IconWeight and Dimensions
led keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
nx-148e lcd keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
metal enclosure dimension9.25" Wide, 8.25" High, 3.50" Deep