EasyManuals Logo
Home>GE>Control Panel>NetworX NX-6V2

GE NetworX NX-6V2 User Manual

GE NetworX NX-6V2
52 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #42 background imageLoading...
Page #42 background image
42
NX-6V2 Control
Tone Sniff Answering Machine Defeat
If enabled, only one call is required to defeat the answering machine. To use this feature you must have a Hayes 1200 Smart Modem.
From the computer, call the panel as normal. When the answering machine answers, the panel will hear the tones from the modem and
seize the phone line for a download. (Loc 21, pg 15)
Two Call Answering Machine Defeat
This is not recommended for commercial applications.
If enabled, to defeat an answering machine, two telephone calls must be made to the premises. On the first call, let the phone ring one
or two times. The control panel will detect these rings and start a 45-second timer, during which, the control panel will answer the next
call on the first ring. (Loc 21, pg 15)
Walk-Test Mode
If enabled, entering [r] [Chime] followed by a user code will allow a walk-through zone test where all zones become silent and local
(non-reporting). During this test the chime light will flash on the LED keypad. Each time a zone is faulted, the zone light on the LED
keypad will illuminate and the chime will sound. The number of the faulted zone(s) will be displayed on the LCD keypad. It will also be
entered into alarm memory and the internal log. To exit at any time during this mode, enter a user code. Otherwise the AWalk-Test
Mode@ will automatically exit after 15 minutes. (Loc 41, pg 20)
Wireless Sensor Missing/Low Battery
The NX-6V2 will send a report to the central station when a wireless sensor has detected a low battery or has not reported to the
receiver. The "Service" LED will illuminate when either condition exists. (Loc 37, pg 18)
Zone Activity Monitor
This feature will send a report to the central station when a particular zone does not change conditions within the specified number of
days programmed. (Loc 40 & 110-169 pg 19 & 25-29).
Zone Bypassed Sounder Alert
If this feature is enabled, the NX-6V2 will beep the keypad sounder upon arming if a zone is bypassed. (Loc 23, pg 15)
Zone Doubling
This feature allows you to use the six zones on the panel as twelve normally closed zones. When this feature is used, zone seven
cannot be a two-wire smoke zone, and European double E.O.L. configuration cannot be used.. THIS FEATURE DOES NOT
INCREASE THE TOTAL NUMBER OF AVAILABLE ZONES BEYOND 16. Zones 7-12 should not be programmed as a “Fire”
zone type when Zone Doubling is used. If one of the twelve zones must be a fire zone, it must be one of Zones 1 to 6. The
corresponding upper zone will become unavailable. For example: if Zone 6 is a fire zone, then Zone 12 will not be available. (Loc 37,
pg 18)
Zone Types (Configurations)
The NX-6V2 has 30 programmable Zone Types that determine how each zone will function and report. The default Zone Types are
listed on page 16. (Loc 111-169, pg 25-29)

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6V2 and is the answer not in the manual?

GE NetworX NX-6V2 Specifications

Power IconPower
operating power16.5 VAC 40, or 50 VA Transformer
auxiliary power with 25 VA Transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA Transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E Power Supply12 VDC Regulated 2 AMPS + Control Panel Power
Loop Specifications IconLoop Specifications
loop resistance standard loop300 Ohms Maximum
loop resistance 2-wire smokes30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Keypad Specifications IconKeypad Specifications
LED keypad current draw130 mA max.
LED keypad zones normal without sounder55 mA
LED keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
NX148E LCD keypad current draw110 mA max.
NX148E LCD keypad without sounder75 mA
NX148E LCD keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
Dimensions and Weight IconDimensions and Weight
metal enclosure dimension11.25" Wide, 11.25" High, 3.50" Deep
shipping weight9 lbs.

Related product manuals