46
NX-6V2 Control
XX. LOCAL TELEPHONE COMPANY INTERFACE INFORMATION
TELEPHONE CONNECTION REQUIREMENTS
Except for telephone company provided ringers, all connections to the telephone network shall be made through standard plugs and
standard telephone company provided jacks or equivalent in such a manner as to allow for immediate disconnection of the terminal
equipment. Standard jacks shall be so arranged that if the plug connected thereto is withdrawn, no interference to the operation of the
equipment at the customer’s premises, which remains connected to the telephone network, shall occur by reason of such withdrawal.
INCIDENCE OF HARM
Should terminal equipment or protective circuitry cause harm to the telephone network, the telephone company shall, where practical,
notify the customer that temporary discontinuance of service may be required. However, where prior notice is not practical, the
telephone company may temporarily discontinue service if such action is deemed reasonable in the circumstances. In the case of such
temporary discontinuance, the telephone company shall promptly notify the customer who will be given the opportunity to correct the
situation. The customer also has the right to bring a complaint to the FCC if he feels the disconnection is not warranted.
CHANGES IN TELEPHONE COMPANY EQUIPMENT OR FACILITIES
The telephone company may make changes in its communications facilities, equipment, operations, or procedures where such action
is reasonably required and proper in its business. Should any such change render the customers terminal equipment incompatible with
the telephone company facilities, the customer shall be given adequate notice to make modifications to maintain uninterrupted service.
GENERAL
The FCC prohibits customer-provided terminal equipment to be connected to party lines.
IMPORTANCE OF THE RINGER EQUIVALENCE NUMBER
The Ringer Equivalence Number (REN) of this device is 0.1B. This number is a representation of the electrical load that it applies to
your telephone line.
MALFUNCTION OF THE EQUIPMENT
In the event that the device should fail to operate properly, the customer shall disconnect the equipment from the telephone line to
determine if it is the customers’ equipment that is not functioning properly. If the problem is with the device, the customer shall
discontinue use until it is repaired.
EQUIPMENT INFORMATION
Manufacturer Of Connecting Equipment: CADDX CONTROLS, INC.
FCC Registration Number: US:GCQAL01BNX-V2, RINGER EQUIVALENCE: 0.1 B
XXI. INDUSTRY CANADA INFORMATION
NOTICE
: The Industry Canada label identifies certified equipment. This certification means that the equipment meets
telecommunications network protective, operational and safety requirements as prescribed in the appropriate Terminal Equipment
Technical Requirements document(s). The Department does not guarantee the equipment will operate to the user’s satisfaction.
Before installing this equipment, users should ensure that it is permissible to be connected to the facilities of the local
telecommunications company. The equipment must also be installed using an acceptable method of connection. The customer should
be aware that compliance with the above conditions might not prevent degradation of service in some situations.
Repairs to certified equipment should be coordinated by a representative designated by the supplier. Any repairs or alternations made
by the user to this equipment, or equipment malfunctions, may give the telecommunications company cause to request the user to
disconnect the equipment.
Users should ensure for their protection that the electrical ground connections of the power utility, telephone lines and internal metallic
water pipe system, if present, are connected together. This precaution may be particularly important in rural areas.
Caution: Users should not attempt to make such connections themselves, but should contact the appropriate electrical inspection
authority, or electrician, as appropriate.
The Ringer Equivalence Number (REN) of this device is 0.1B. This number is a representation of the electrical load that it applies to
your telephone line. NOTICE
: The Ringer Equivalence Number (REN) assigned to each terminal device provides an indication of the
maximum number of terminals allowed to be connected to a telephone interface. The termination on an interface may consist of any
combination of devices subject only to the requirement that the sum of the Ringer Equivalence Numbers of all the devices does not
exceed 5.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6V2 and is the answer not in the manual?

GE NetworX NX-6V2 Specifications

Power IconPower
operating power16.5 VAC 40, or 50 VA Transformer
auxiliary power with 25 VA Transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA Transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E Power Supply12 VDC Regulated 2 AMPS + Control Panel Power
Loop Specifications IconLoop Specifications
loop resistance standard loop300 Ohms Maximum
loop resistance 2-wire smokes30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Keypad Specifications IconKeypad Specifications
LED keypad current draw130 mA max.
LED keypad zones normal without sounder55 mA
LED keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
NX148E LCD keypad current draw110 mA max.
NX148E LCD keypad without sounder75 mA
NX148E LCD keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
Dimensions and Weight IconDimensions and Weight
metal enclosure dimension11.25" Wide, 11.25" High, 3.50" Deep
shipping weight9 lbs.