NX-6V2 Control 7
VI. PROGRAMMING THE LED KEYPADS
KEYPAD ADDRESS AND PARTITION
This section describes how to program the address and partition of each keypad as well as the options that are available. The address of
the keypad is important because this is how the panel supervises the keypads.
The factory default for the Master code is [1]-[2]-[3]-[4] when using a 4-digit code or [1]-[2]-[3]-[4]-[5]-[6] for a 6-digit code. The factory
default for the "Go To Program" code is [9]-[7]-[1]-[3]
for a 4-digit code or [9]-[7]-[1]-[3]-[0]-[0] for a 6-digit code.
[r] [9] [2] (Applies to LED keypad ONLY)
Enter [r] [9] [2] [program code].
Enter the zone number (1 - 16) you want the keypad to start at.
Enter [r] to save and exit.
[r]-[9]-[3] Set keypad options
Enter [r]-[9]-[3] [program code]. The "Service" LED will flash.
LEDs 1-8 can now be toggled on/off to enable/disable the following functions:
After enabling/disabling the desired functions press [r]
LED KEYPAD FEATURE ENABLED
1
RESERVED...DO NOT PROGRAM THIS AT ALL!
2 ENABLE SILENT KEYPAD OPTION
Silences the entry/exit sounder & chime only.
3 ENABLE DING-DONG SOUND FOR CHIME
If off, chime will be a single tone. (See location 40, page 19)
4 ENABLE KEYPRESS SILENCE OPTION
Silences the pulsing keypad sounder for 5 seconds when a key is pressed)
5 ENABLE ARMED STATUS SUPPRESSION
Will not allow the keypad to display faulted or bypassed zones when the system is armed)
6 ENABLE PANIC, FIRE, MEDICAL BEEPTONE
Will sound a short beep to verify that the keypress was accepted)
7
SUPPRESSES THE "SERVICE" LED (NOTE: For UL installations, the Service LED shall not be suppressed.)
Will not allow the "Service" LED to illuminate for any reason. If there is a system trouble, pressing [r]-[2] will
still show the service menu.)
8 ENABLE MULTI-PARTITION VIEWING
Enables temporary viewing of all partitions by pressing [r]-[1]-[partition number])
[r]-[9]-[4] Set Keypad Number and Partition
Enter [r]-[9]-[4]-[program code]. The "Service" LED and the "Instant" LED will flash.
Enter the keypad number (1-8)
Press [r]. The "Instant" LED will illuminate steady and the "Service" LED will remain flashing.
Enter the partition number for the keypad. The keypad will automatically exit this mode at this time.
[r]-[9]-[5] Set elapsed increments since last autotest
Enter [r]-[9]-[5]-[program code]. The "Service" LED will flash.
Enter [100's digit] -[10's digit]-[1's digit]-[#]
[r]-[9]-[6] Set system date
Enter [r]-[9]-[6]-[master code]. The "Service" LED will flash.
Enter [day of week (1=Sun)]-[month 10's digit]-[month 1's digit]-[day 10's digit] [day 1's digit] -[year 10's digit]-[year 1's digit]
[r]-[9]-[7] Set system clock
Enter [r]-[9]-[7]-[master code]. The "Service" LED will flash.
Enter [hour 10's digit]-[hour 1's digit]-[minutes 10's digit]-[minutes 1's digit]
CHANGING USER CODES:
Enter [r]-[5]-[master code]. The "Ready" LED will flash.
Enter the 2-digit user number (i.e. “03” for user 3). Maximum number of users is 40.
Enter the new user code designated for that individual. The "Ready" LED will flash indicating that the code was accepted. If it
rejects the code, the sounder will beep 3 times.
If another user code needs to be programmed, return to step 2.
Press [#] while the "Ready" LED is flashing to exit the User Code Programming Mode.

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6V2 and is the answer not in the manual?

GE NetworX NX-6V2 Specifications

Power IconPower
operating power16.5 VAC 40, or 50 VA Transformer
auxiliary power with 25 VA Transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA Transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E Power Supply12 VDC Regulated 2 AMPS + Control Panel Power
Loop Specifications IconLoop Specifications
loop resistance standard loop300 Ohms Maximum
loop resistance 2-wire smokes30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Keypad Specifications IconKeypad Specifications
LED keypad current draw130 mA max.
LED keypad zones normal without sounder55 mA
LED keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
NX148E LCD keypad current draw110 mA max.
NX148E LCD keypad without sounder75 mA
NX148E LCD keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
Dimensions and Weight IconDimensions and Weight
metal enclosure dimension11.25" Wide, 11.25" High, 3.50" Deep
shipping weight9 lbs.