Page #44 background imageLoading...
Page #44 background image
44
NX-6V2 Control
XVII. APPENDIX 2
REPORTING ZONE CODES IN SIA OR CONTACT ID
The NX-6V2 has the ability to report SIA level 1 transmissions to either or both phone numbers. Each report in SIA consists of an Event
Code and a Zone or User ID. The Zone ID will be the zone number that is in alarm. The event code will come from the chart below and
be programmed in the zone type event code.
Programmed Event Code SIA Code Description
0 .......................................................HA ..............................................................Holdup Alarm
1 .......................................................FA...............................................................Fire Alarm
2 .......................................................PA ..............................................................Panic alarm
3 .......................................................BA ..............................................................Burglary Alarm
4 .......................................................BA ..............................................................Burglary Alarm
5 .......................................................BA ..............................................................Burglary Alarm
6 .......................................................UA ..............................................................Untyped Alarm
7 .......................................................BA ..............................................................Burglary Alarm
8 .......................................................BA ..............................................................Burglary Alarm
9 .......................................................UA ..............................................................Untyped Alarm
10 ......................................................HA ..............................................................Holdup Alarm
11 ......................................................MA..............................................................Medical Alarm
12 ......................................................PA ..............................................................Panic alarm
13 ......................................................TA...............................................................Tamper Alarm
14 ......................................................RP ..............................................................Periodic Test
15 ......................................................GA ..............................................................Gas Alarm
16 ......................................................KA ..............................................................Heat Alarm
17 ......................................................WA .............................................................Water Alarm
18 ......................................................QA ..............................................................Emergency Alarm
19 ......................................................SA ..............................................................Sprinkler Alarm
20 ......................................................ZA...............................................................Freeze Alarm
21 ......................................................KH ..............................................................High Temp Alarm
22 ......................................................FA...............................................................Manual Fire Alarm
The NX-6V2 has the ability to report Ademco Contact ID transmissions. Each report in Contact ID consists of an Event Code and a
Zone ID. The zone ID is the zone that created the alarm. The event code will come from the chart below and be programmed in the
zone type event code.
Programmed Event Code Contact ID Code Description
0 .......................................................122 .............................................................Silent Panic
1 .......................................................110 .............................................................Fire Alarm
2 .......................................................120 .............................................................Panic alarm
3 .......................................................130 .............................................................Burglary Alarm
4 .......................................................131 .............................................................Perimeter Alarm
5 .......................................................132 .............................................................Interior Alarm
6 .......................................................133 .............................................................24 Hour Burglary
7 .......................................................134 .............................................................Entry Alarm
8 .......................................................135 .............................................................Day/Night Alarm
9 .......................................................150 .............................................................Non Burglary 24 Hour
10 ......................................................121 .............................................................Duress Alarm
11 ......................................................100 .............................................................Medical Alarm
12 ......................................................123 .............................................................Audible Panic Alarm
13 ......................................................137 .............................................................Tamper Alarm
14 ......................................................602 .............................................................Periodic Test
15 ......................................................151 .............................................................Gas Detected
16 ......................................................158 .............................................................High Temp
17 ......................................................154 .............................................................Water Leakage
18 ......................................................140 .............................................................General Alarm
19 ......................................................140 .............................................................General Alarm
20 ......................................................159 .............................................................Low Temp
21 ......................................................158 .............................................................High Temp Alarm
22 ......................................................115 .............................................................Manual Fire Alarm

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the GE NetworX NX-6V2 and is the answer not in the manual?

GE NetworX NX-6V2 Specifications

Power IconPower
operating power16.5 VAC 40, or 50 VA Transformer
auxiliary power with 25 VA Transformer12 VDC Regulated 500 mA
auxiliary power with 40 or 50 VA Transformer12 VDC Regulated 1 AMP
auxiliary power with NX-320E Power Supply12 VDC Regulated 2 AMPS + Control Panel Power
Loop Specifications IconLoop Specifications
loop resistance standard loop300 Ohms Maximum
loop resistance 2-wire smokes30 Ohms Maximum
loop responseSelectable 50mS or 500mS
Operating Environment IconOperating Environment
operating temperature32 to 120 degrees F
Keypad Specifications IconKeypad Specifications
LED keypad current draw130 mA max.
LED keypad zones normal without sounder55 mA
LED keypad dimensions6.4" Wide, 4.0" High, 1.1" Deep
NX148E LCD keypad current draw110 mA max.
NX148E LCD keypad without sounder75 mA
NX148E LCD keypad dimensions6.4" Wide, 5.3" High, 1.0" Deep
Dimensions and Weight IconDimensions and Weight
metal enclosure dimension11.25" Wide, 11.25" High, 3.50" Deep
shipping weight9 lbs.