Programming a new wash program 43
Code 429159
Rev. 15/0717
7.3.13. Cooling gradient
Optional programming
This function only appears if the COOLING GRADIENT parameter has been activated in the CONFIGURATION
menu and if gradual cooling YES has been programmed in the previous stage.
Controlling the cooling of the bath is possible in different gradients defined in degrees/minute.
The water temperature can modify the cooling speed, mainly in the fastest gradients.
Cooling gradients
Value in Centigrade degrees: 1º / minute
Value in Fahrenheit degrees: 2.0º / minute
Value in Centigrade degrees: 3º / minute
Value in Fahrenheit degrees: 5.5º / minute
<<< Option programmed by default
Value in Centigrade degrees: 5º / minute
Value in Fahrenheit degrees: 9º / minute
Value in Centigrade degrees: 10º / minute
Value in Fahrenheit degrees: 18º / minute
7.3.14. Draining
This function opens the drain valve.
The drum rotation speed during draining and the drain time are programmed in successive operations.
Possible programming:
Yes, draining in the phase
<<< Option programmed by default
Optional programming
Machines with double drain
Using the double drain requires:
option previously installed in the washing machine
configuration of two valves option in the corresponding DRAIN step in SETUP menu
Possible programming:
Main drain draining
<<< Option programmed by default
Machines with recovery tank
Pump and valve drain system designed to be connected to a recovery tank.
Operating this system requires:
double drain set (valve + pump) corresponding to AS recovery tank
configuration of valve + pump option in the corresponding DRAIN step in SETUP menu
Possible programming:
Main drain draining
<<< Option programmed by default
Pump to tank draining
NOTE. To avoid the pump working without bath, after a draining time, the pump stops and opens
drain valve 1.
7.3.15. Draining speed
Programming this function is only possible if draining has been programmed.