10 Technical Parameters
47
10 Technical Parameters
Technical Data GW12KLV-MT GW15KLV-MT GW20KLV-MT
Input
Max. Input Power (kW) 15.6 19.5 26
Max. Input Voltage (V) 800
MPPT Operating Voltage Range (V) 200~650
MPPT Voltage Range at Nominal
Power (V)
360~600
Start-up Voltage (V) 180
Nominal Input Voltage (V) 370
Max. Input Current per MPPT(A) 30 or 25
*1
Max. Short Circuit Current per MPPT
(A)
37.5 or 31.3
*1
Max. Backfeed Current to The Array (A) 0
Number of MPP Trackers 3
Number of Strings per MPPT 2/2/2
Output
Nominal Output Power (kW) 12 15 20.7
Nominal Output Apparent Power (kVA) 12 15 20.7
Max. AC Active Power (kW)
11.3@208V
12@220V
13.1@240V
14.4@208V
15@220V
16.6@240V
19.6@208V
20.7@220V
22.6@240V
Max. AC Apparent Power (kVA) 13.1 16.6 22.6
Nominal Power at 40℃ (kW) (Only for
Brazil)
12 15 20.7
Max Power at 40℃ (Including AC
Overload)( kW) (Only for Brazil)
12 15 20.7
Nominal Output Voltage (V) 220V, 3L/N/PE or 3L/PE
Output Voltage Range (V) 150~300
Nominal AC Grid Frequency (Hz) 50/60
AC Grid Frequency Range (Hz) 47.5~51.5/57~61.8
Max. Output Current (A) 31.5 40.0 54.5

Other manuals for Goodwe SMT Series

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Goodwe SMT Series and is the answer not in the manual?

Goodwe SMT Series Specifications

General IconGeneral
BrandGoodwe
ModelSMT Series
CategoryInverter
LanguageEnglish

Related product manuals