Repair
3A2989V 29
Set Up a New Radar Level Sensor
Level sensors need to have three settings setup after installing on the tank of the PFP machine. The tank must be
empty, or the level needs to be at least below the bottom of the installed probe with the tank cover closed.
1. Open the sensor head cover over the display:
a. Loosen the securing clamp with an Allen wrench (if clamp is present).
b. Unscrew the round cover and pull away.
Use the operating keys to navigate within the operating menu and to select options from a list.
2. Turn power on the machine. Set EMPTY CAL, then FULL CAL, then do a mapping of the Empty Tank.
3. Set EMPTY CAL to .939 meters:
a. Press E, then +, +, to get to Set Up. Then press E to get to EMPTY CAL, then press E.
b. Press + until decimal point (.) appears, then press E.
c. Press + until 9 appears, then press E.
d. Press + until 3 appears, then press E.
e. Press + until 9 appears, then press E.
f. Press and hold E until the hourglass appears, then release.
Key Meaning
“Minus” Key
• In a selection list, this key will move the selection bar upward.
• In an input matrix, this key will move the selection bar backward.
“Plus” Key
• In a selection list, this key will move the selection bar downward.
• In an input matrix, this key will move the selection bar forward.
“Enter” Key
• Opens the marked sub-menu or parameter.
• Confirms a changed parameter value.
“Escape” Key combination (press keys simultaneously)
• Closes a parameter without accepting the changes.
• Quits the current menu layer and returns to the next higher layer.