EasyManuals Logo

Gree GWH12QB-K3DNA6O User Manual

Gree GWH12QB-K3DNA6O
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #63 background imageLoading...
Page #63 background image
60
Installation and Maintenance
Service Manual
No.
Malfunction
Name
Display Method of Indoor Unit
A/C Status Possible Causes Countermeasures
Display
of dual-
8 nixie
tube
Indicator Display
(during blinking, ON
0.5s and OFF 0.5s)
Operation
Indicator
Heat
Indicator
1
High pressure
protection
E1
Flash
once
every 3s
During cooling and drying
operation, compressor and
outdoor fan stop while indoor
fan operates. During heating
operation, all loads stop.
Refrigerant is
superabundant;
1. Reduce refrigerant
volume;
Poor heat-
exchanging (including
heat exchanger is
dirty and radiating
environment is not
good);
2. Clean the heat
exchanger; improve
radiating environment
of unit;
Ambient temperature
is too high;
3. Reduce load
Poor connection of
LPP;
4. After de-energization,
reinsert LPP terminal
tightly;
Pressure switch is
damaged;
5. Replace pressure
switch;
Hardware malfunction
of outdoor units main
board;
6. Replace outdoor
units main board;
2
Freeze
protection
E2
Flash
twice
every 3s
During cooling and drying
operation, compressor and
outdoor fan stop while indoor
fan operates. During heating
operation, all loads stop.
Poor air return of
indoor unit;
1. Check whether indoor
units horizontal louver
can close normally;
Rotation speed
of indoor fan is
abnormal;
2. Replace indoor units
main board→ replace
indoor fan
Evaporator is dirty;
3. Clean evaporator of
indoor unit;
9. Maintenance
9.1 Error Code List

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH12QB-K3DNA6O and is the answer not in the manual?

Gree GWH12QB-K3DNA6O Specifications

General IconGeneral
BrandGree
ModelGWH12QB-K3DNA6O
CategoryAir Conditioner
LanguageEnglish

Related product manuals