EasyManuals Logo
Home>Gree>Air Conditioner>GWH12QB-K3DNA6O

Gree GWH12QB-K3DNA6O User Manual

Gree GWH12QB-K3DNA6O
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #85 background imageLoading...
Page #85 background image
82
Installation and Maintenance
Service Manual
7. Communication malfunction
Main detection points:
Check if the connection wire and the built-in wiring of indoor and outdoor unit are connected well and without damage;
If the communication circuit of indoor mainboard is damaged? If the communication circuit of outdoor mainboard (AP1)
is damaged?
Malfunction diagnosis process:
(12) Communication malfunction
Main detection points:
ƽ
Check if the connection wire and the built-in wiring of indoor and outdoor unit are connected well and without damage;
ƽ
If the communication circuit of indoor mainboard is damaged? If the communication circuit of outdoor mainboard (AP1) is damaged?
Malfunction diagnosis process:
Start
If the unit operates normally
before malfunction
Check built-in wiring
of indoor and outdoor
unit
If the wiring is
damaged?
Replace the
wire
Check the malfunction
type with communication
malfunction detector
Malfunction of outdoor
communication circuit
Replace outdoor
mainboard AP1
Replace indoor
mainboard AP2
Is the malfunction
eliminated?
Is the malfunction
eliminated?
End
Check the connection
wire according to the
wiring diagram.
Reconnect the wire or
replace the connection
wire according to the
wiring diagram.
Is the malfunction
eliminated?
If the connection wire
is connected well?

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH12QB-K3DNA6O and is the answer not in the manual?

Gree GWH12QB-K3DNA6O Specifications

General IconGeneral
BrandGree
ModelGWH12QB-K3DNA6O
CategoryAir Conditioner
LanguageEnglish

Related product manuals