EasyManuals Logo
Home>Gree>Air Conditioner>GWH12QB-K3DNA6O

Gree GWH12QB-K3DNA6O User Manual

Gree GWH12QB-K3DNA6O
114 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #8 background imageLoading...
Page #8 background image
5
Technical Information
Service Manual
2.4 Cooling and Heating Data Sheet in Rated Frequency
Rated cooling
condition(
o
C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor Outdoor P (MPa) T1 (
o
C) T2 (
o
C)
27/19 35/24
12K 0.8 ~ 1.1 11 to 14 38 to 41
Super High High
72
18K 0.8 ~ 1.0 12 to 14 80 to 40 52
Rated heating
condition(
o
C)
(DB/WB)
Model
Pressure of gas pipe
connecting indoor and
outdoor unit
Inlet and outlet pipe
temperature of heat
exchanger
Fan speed of
indoor unit
Fan speed of
outdoor unit
Compressor
frequency
(Hz)
Indoor Outdoor P (MPa) T1 (
o
C) T2 (
o
C)
20/15 7/6
12K 2.8 ~ 3.2 38 to 41 2 to 5
Super High High
77
18K 2.2 ~ 2.4 70 to 40 1 to 5 65
Instruction:
T1: Inlet and outlet pipe temperature of evaporator
T2: Inlet and outlet pipe temperature of condenser
P: Pressure at the side of big valve
Connection pipe length: 5 m.
Cooling:
Heating:
2.5 Noise Curve
Indoor side noise
60
50
40
30
20
10
0
Indoor Fan Motor Rotating Speed
Noice/dB(A)
low
Middle
High Super High
Outdoor side noise
Compressor frequency/Hz
Noise/dB(A)
70
60
50
40
30
02040608
0100
20
18K12K

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Gree GWH12QB-K3DNA6O and is the answer not in the manual?

Gree GWH12QB-K3DNA6O Specifications

General IconGeneral
BrandGree
ModelGWH12QB-K3DNA6O
CategoryAir Conditioner
LanguageEnglish

Related product manuals