97
Installation and Maintenance
Service Manual
11. Removal Procedure
11.1 Removal Procedure of Indoor Unit
Caution: discharge the refrigerant
completely before removal.
Axile bush
Push out the axile bush on horizontal
louver. Bend the horizontal louver with
hand and then separate the horizontal
louver from the crankshaft of step motor
to remove it.
Horizontal louver
Location of step motor
ProcedureStep
1. Remove fi lter assembly
2. Remove horizontal louver
Front panel
Front
case
Right fi lter
Groove
Left lter
Open the front panel. Push the left fi lter
and right lter until they are separate from
the groove on the front panel.
Remove the left lter and right lter
respectively.
3. Remove panel
Front case
sub-assy
Panel
Groov
e
Panel rotation
Screws
Display
Open the front panel; separate the panel
rotation shaft from the groove fixing the
front panel and then removes the front
panel.