7.1.2 Country setting
Country setting
When the inverter start up,we need to select the right country,if
we don’t select any country, the inverter will run under
AS/NZS4777.2 as default for Australia,or run under
VDE0126-1-1 for other region after 30s.
When inverter powered on, OLED will light automatically. Once the PV power is
sufficient, OLED displays the following:
Growatt
PV inverter
Set Country
XXXX
Press the touch key once a second to scroll through the different Country, showing on
the screen will constantly change.For example, if you want to choose Newzealand,
press the control key until the OLED display shows “Newzealand” as below:
Press the touch key 5S, the OLED shows Country setting is complete.
7.1.3 Enabling/Disabling Power Quality Response Modes
(PQRM)
PQRM setting
When the Country setting is complete,we need to select the right
Power Quality Response Mode,if we don’t select any mode, the
inverter will run under default mode different from region.
MIN TL-X contains five types Power Quality Response Modes:
Volt-Var, Volt-watt, Fixed PF, Reactive power, Power limit. When the Country setting
is complete, the screen will display Power Quality Response Modes setting.