Page 8
2. High Salt LED ON
The ‘High Salt’ LED will be ON when the cell amperage is above the maximum limit. The ‘High Salt’ LED may also
be ON if the wrong Turbo Cell is being used. The Aqua Trol systems are designed to only work with the t-5 model.
The LCD display will read ‘HI’ when the amperage is above 6.40.
Verify salt level is 2700-3400ppm and check
with independent test to ensure accuracy.
If salt level is above the range, partially drain pool and/or spa and refill
with fresh water to achieve a salt level of 3200ppm, refer to page 9,
Step D. If the salt level is not high, verify the correct cell is being used
then reset (follow steps on page 6).
Maximum Current (Amps)
before shutdown
Unlike low salt the system does
not shut the chlorinator down
when a specific salt level is
reached. Instead the unit will
suspend chlorination when the
cell’s amperage draw exceeds a
certain value.
T
-CELL-5
6.40