316 Using Touch Probe Cycles
13.2 Before You Start Working with Touch Probe Cycles
Consider a basic rotation in the Manual
Operation mode: MP6166
Set MP 6166 = 1 for the TNC to consider an active basic rotation
during the probing process (the workpiece is approached along an
angular path if required) to ensure that the measuring accuracy for
probing individual positions is also increased in Setup mode.
Multiple measurement: MP6170
To increase measuring certainty, the TNC can run each probing
process up to three times in sequence. If the measured position
values differ too greatly, the TNC outputs an error message (the limit
value is defined in MP6171). With multiple measurement it is possible
to detect random errors, e.g. from contamination.
If the measured values lie within the confidence interval, the TNC
saves the mean value of the measured positions.
Confidence interval for multiple measurement:
MP6171
In MP6171 you store the value by which the results may differ when
you make multiple measurements. If the difference in the measured
values exceeds the value in MP6171, the TNC outputs an error
message.
This feature is not active during the following functions in
the Manual Operation mode:
îš„ Calibrate length
îš„ Calibrate radius
îš„ Measure basic rotation

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING and is the answer not in the manual?

HEIDENHAIN ITNC 530 - CYCLE PROGRAMMING Specifications

General IconGeneral
BrandHEIDENHAIN
ModelITNC 530 - CYCLE PROGRAMMING
CategoryControl Panel
LanguageEnglish

Related product manuals