25
25
If the speed of the moving objects is normal, you can
choose NORM.
If the speed of the moving objects is high, you can choose
FAST and FASTER.
When the IRIS value is ALC and the SHUTTER value is 1/50,
1/120, 1/250, 1/500, 1/1K, 1/2K, 1/4K, 1/10K, the AGC value
is not adjustable.
When the IRIS value is MANUAL and the SHUTTER value is
1/50, 1/120, 1/250, 1/500, 1/1K, 1/2K, 1/4K, 1/10K, the AGC
value can be set to LOW, HIGH, OFF.
When the IRIS value is ELC, the AGC value can be set to LOW,
HIGH, OFF.
3.2.7 WB Setting (White Balance)
This feature processes the viewed image to retain co lor balance
over a color temperature range and remove the unrealistic color
casts. The WB mode can be set to ATW1, ATW2, ATC, and
Manual. . . .
ATW1: The Auto Tracking White Balance. In the ATW mode,
white balance is continuously being adjusted in real-time
according to the color temperature of the scene illumination.
The color temperature range of the ATW1 mode is from 1800K
to 10500K.
ATW2: The Auto Tracking White Balance. In the ATW mode,
white balance is continuously being adjusted in real-time
according to the color temperature of the scene illumination.