Thermal & Optical Bi-spectrum PTZ Network Camera User Manual
39
3. Select Alarm Input NO. and Alarm Type from the dropdown list. Edit the Alarm Name.
4. Refer to Set Arming Schedule for setting scheduled time. Refer to Linkage Method Settings for
setting linkage method.
5. Click Copy to... to copy the settings to other alarm input channels.
6. Click Save.
7.4 Set Exception Alarm
Exception such as network disconnection can trigger the device to take corresponding action.
Steps
1. Go to Configuration → Event → Basic Event → Exception.
2. Select Exception Type.
The IP address of current device is same as that of other device in the
network.
Incorrect user name or password is entered.
The power supply voltage is fluctuating.
The panning and tilting movements are stuck.
3. Refer to Linkage Method Settings for setting linkage method.
4. Click Save.
7.5 Set Burning-Prevention
This function is used to close the shutter to prevent the lens from high temperature damage.
Steps
1. Go to Configuration → Event → Basic Event → Burning-Prevention.
2. Check Enable.
3. Select burning-prevention mode.
Lens Movement
The lens move automatically to avoid high temperature damage.
4. Set the protection duration and protection delay.
5. Click Save.