Before You Start
●
Go to VCA and select the applicaon. Select Smart Event and click Next to enable the funcon.
●
For the device supporng HEOP, go to VCA to import and enable Smart Event.
Steps
1.
Go to VCA → Set
Applicaon → Smart Event → Region Exing Detecon .
2.
Check Enable.
3.
Click Add to add a rule and set a
detecon area.
1) Draw a detecon area. Click , click on the live view to specify the vertexes and draw the
boundaries of the
detecon area, and right click to complete drawing.
2) Set the minimum size and the maximum size for the target to improve detecon accuracy.
Only targets whose size are between the maximum size and the minimum size trigger the
detecon. Click and , then drag the mouse in the live view to draw the minimum and
maximum target size.
3)
Oponal: Click to delete all the seng areas.
4.
Set parameters.
Detecon Target
This funcon allows alarm triggering by specied selected target types. If the detecon target
is not selected, all the detected targets will be reported.
Note
This funcon is only available for certain device models under certain sengs. Please refer to
the actual sengs.
Sensivity
It stands for the percentage of the body part of an acceptable target that goes across the
predened region. Sensivity = 100 - S1/ST × 100. S1 stands for the target body part that goes
across the predened region. ST stands for the complete target body. The higher the value of
sensivity is, the more easily the alarm can be triggered.
Target Validity
If you set a higher validity, the required target features should be more obvious, and the
alarm accuracy would be higher. The target with less obvious features would be missing.
Network Camera User Manual