User Manual of Digital Video Recorder
8.1 Setting Motion Detection
Steps:
1.
Enter Motion Detection interface of Camera Management and choose a camera you want to set up motion
detection.
Menu> Camera> Motion
Figure 8. 1 Motion Detection Setup Interface
2.
Set detection area and sensitivity.
Check checkbox to enable motion detection, use the mouse to draw detection area(s) and drag the
sensitivity bar to set sensitivity.
Click to set alarm response actions.
Figure 8. 2 Set Detection Area and Sensitivity
3.
Click
Trigger Channel
tab and select one or more channels which will start to record or become
full-screen monitoring when motion alarm is triggered.
Figure 8. 3 Set Trigger Camera of Motion Detection
4.
Set arming schedule of the channel.
Select
Arming Schedule
tab to set the channel’s arming schedule.
Choose one day of a week and up to eight time periods can be set within each day. Or you can click the
Copy
button to copy the time period settings to other day(s).

Table of Contents

Other manuals for HIKVISION DS-7332HGHI-SH

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-7332HGHI-SH and is the answer not in the manual?

HIKVISION DS-7332HGHI-SH Specifications

General IconGeneral
HDD capacity18000 GB
HDD interfaceSerial ATA
Number of HDDs supported4
Product colorBlack
Channels quantity32 channels
Maximum frame rate30 fps
Video compression formatsH.264
Playback resolutions supported1920x1080, 1280x1024, 1280x720, 1024x768, 704x576, 704x480
BNC input ports32
USB 2.0 ports quantity3
Ethernet interface typeGigabit Ethernet
Supported network protocolsTCP/IP, PPPoE, DHCP, EZVIZ Cloud P2P, DNS, DDNS, NTP, SADP, SMTP, SNMP, NFS, iSCSI, UPnP, HTTPS
Power requirements100-240V AC, 47 - 63Hz
Operating temperature (T-T)-10 - 55 °C
Operating relative humidity (H-H)10 - 90 %
Weight and Dimensions IconWeight and Dimensions
Dimensions (WxDxH)445 x 390 x 70 mm