User Manual of Network Video Recorder
217
7. Select the Group number for the current HDD.
The default group No. for each HDD is 1.
8. Click the OK button to confirm the settings.
Figure 14. 16 Confirm HDD Group Settings
9. In the pop-up Attention box, click the Yes button to finish the settings.
14.4.2 Setting HDD Property
Purpose:
The HDD property can be set to redundancy, read-only or read/write (R/W). Before setting the HDD property,
please set the storage mode to Group (refer to step1-4 of Chapter Setting HDD Groups ).
A HDD can be set to read-only to prevent important recorded files from being overwritten when the HDD becomes
full in overwrite recording mode.
When the HDD property is set to redundancy, the video can be recorded both onto the redundancy HDD and the
R/W HDD simultaneously so as to ensure high security and reliability of video data.
Steps:
1. Enter the HDD Information interface.
Menu > HDD> General
2. Select HDD from the list and click the icon to enter the Local HDD Settings interface, as shown in
Figure 14. 17.
Figure 14. 17 Set HDD Property
3. Set the HDD property to R/W, Read-only or Redundancy.
4. Click the OK button to save the settings and exit the interface.

Table of Contents

Other manuals for HIKVISION DS-8600

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the HIKVISION DS-8600 and is the answer not in the manual?

HIKVISION DS-8600 Specifications

General IconGeneral
BrandHIKVISION
ModelDS-8600
CategoryNetwork Hardware
LanguageEnglish

Related product manuals