7-62
M4GB-07-153
6



When the strainer is disassembled, be sure to replace the
strainer together with the gasket. Install the cover and the
magnet only after sufficiently cleaning them. After being as
-
sembled, closely check the air-tightness of the strainer.

To remove cover (1) , loosen with a spanner. After the cover
is removed, gasket (2), strainer (3), and gasket (4) are easily
removed in order. Wash removed strainer (3) with light oil.
Install the strainer in the reverse order of disassembling. At
that time, install gasket (2) into cover (1) first. Then, securely
tighten cover (1) to pump (5) using a spanner.
NOTE: Wrench size: 17 mm
M1GR-07-004
M4GB-07-155
Fuel Solenoid Pump