40
OPERATION
2.Plug in the appliance.
Most motorized appliances
require more than their rated
wattage for startup.
If the generator is overloaded, or if there is a short circuit in a
connected appliance, or if the inverter is overheated, the red
OVERLOAD ALARM indicator will come ON. The red OVERLOAD
ALARM indicator will stay ON and, after about five seconds, current to
the connected appliance(s) will shut off, and the green OUTPUT
indicator will go OFF. Stop the engine and investigate the problem.
Determine if the cause is a short circuit in a connected appliance, an
overload, or an overheated inverter. Correct the problem and restart the
generator.
Before connecting an appliance to the generator, make sure that it is in
good order and that its electrical rating does not exceed that of the
generator. Then start the generator and connect the appliance power
cord.
When an electric motor is started, the red OVERLOAD ALARM
indicator may come on. This is normal if the red OVERLOAD ALARM
indicator goes OFF after about five seconds. If the red OVERLOAD
ALARM indicator stays ON, consult your servicing dealer.
PLUG
36Z376000.book 40 ージ 014年9月19日 金曜日 午後6時26分

Table of Contents

Other manuals for Honda EU70is

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU70is and is the answer not in the manual?

Honda EU70is Specifications

General IconGeneral
ModelEU70is
TypeInverter
Maximum AC Output7000 VA
Rated AC Output5500 VA
EngineGX390
Engine Displacement389 cc
Fuel TypeGasoline
Run Time per Tankful6.5 hours at rated load
Starter SystemElectric
DC Output12V, 8.3A
Run Time at 1/4 Load18 hours
Noise Level52 dB(A) at 1/4 load
Rated Voltage220-240V