EasyManuals Logo
Home>Honda>Portable Generator>EU70is

Honda EU70is User Manual

Honda EU70is
380 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #47 background imageLoading...
Page #47 background image
44
OPERATION
AC Parallel Operation Applications
Two EU70is generators can be connected together to increase the
available power using a parallel kit (optional equipment).
Follow the instructions included with the parallel kit.
Before connecting an appliance or power cord to the generator:
Make sure that it is in good working order. Faulty appliances or
power cords can create a potential for electrical shock.
If an appliance begins to operate abnormally, becomes sluggish, or
stops suddenly, turn it off immediately. Disconnect the appliance,
and determine whether the problem is the appliance or the rated load
capacity of the generator has been exceeded.
Never connect different generator models.
For parallel operation, use only a Honda approved parallel kit (optional
equipment) when connecting one EU70is to another EU70is
generator.
Never connect or remove the parallel operation cable when the
generator is running.
For single generator operation, the parallel operation cable must be
disconnected from both generators.
36Z376000.book 44 ージ 014年9月19日 金曜日 午後6時26分

Table of Contents

Other manuals for Honda EU70is

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Honda EU70is and is the answer not in the manual?

Honda EU70is Specifications

General IconGeneral
BrandHonda
ModelEU70is
CategoryPortable Generator
LanguageEnglish

Related product manuals